Trinity Operating Procedures - TOPs
TOP-GAGES: Gage Control
Rev: 12/06/2017
Scope: This procedure covers the creation, modification and control of gages, including customer supplied tooling or equipment, used to verify specific dimensions (as opposed to general-purpose instruments such as calipers whose control is covered by TOP-CALIB.)
Procedure:
Note:
"gage" might also be a
customer supplied tool or piece
of equipment. *
"
Forging Engineer" refers to the member of
the
Engineering Department assigned the die in question. If there is any
question as to which
Forging Engineer is assigned a particular die, the
Engineering Manager decides. ** A
"reference gage" is an uncalibrated
device, typically a mating piece provided by the customer, which simply
provides a cross-check on the functionality of the part. Although
reference gages are not controlled by print dimensions, they are
tracked in the gage control system to detect wear.
STEP
WHO
WHEN
INFO TO USE
WHAT TO DO
IF GAGE
PROVIDED BY CUSTOMER, SKIP TO STEP 3
1
Forging Engineer*
As
required
for new die sale, engineering change or QC need
Print(s) and other info deemed appropriate
Explain
to
Machinist what
is needed and issue a Job
Order; when
pulling off prints
from the viewer for Job
Order purposes, Stamp print(s) per
TOP-PRINT.
2
Machinist
Per
schedule agreed to with
Forging Engineer
Job Order;
Print, Sketch or other info
Make
gage
to specifications. Return finished gage to Calibrations Clerk.
3
Calibrations Clerk
Every
6 months
Print(s);
gage; Gage Status Record in Calibration
System
Thoroughly
inspect gage to insure that it properly checks intended dimension(s)
and tolerances; record on Gage Wear Report in Calibration System;
if reference gage** check
for wear (for new one, determine wear tolerances); if thread gage,
visually inspect for damage or wear and, as deemed appropriate, verify
thread pitch diameter (if outside calibration source is needed for this
measurement see TOP-CALIB);
mark rejected gage with REJECT tag; for
new or disapproved gages, provide dimensional report to
Forging Engineer; if
gage being returned
after use in inspection is found to be out of tolerance report per
TOP-RECHK;
if gage approved, go to step 6
4
Forging Engineer
IF
GAGE IS
DISAPPROVED BY CALIBRATIONS
CLERK
Print(s),
Customer Specifications
Determine
degree of changes needed to gage. Go
back to
step 1, or determine course of action with customer if
customer-provided gage.
5
Forging Engineer
Once
gage
fully approved
-
Turn
gage
over to Calibrations Clerk
for Calibration
System
.
6
Calibrations Clerk
Upon
having
verified gage
Forging
or
machining print; gage
Mark
Trinity Forge gages (with laser etch/telesis to include die
number) and attach Calibration
Sticker; enter gage into Calibration
System
; includes customer gage (if gage not already
identified from
customer, request authorization from customer to mark gage with laser
etch/telesis to identify with customer name and our die number, gage
identified as such); apply any safeguard which is deemed appropriate to
safeguard the gage from adjustments which would invalidate the
calibration; attach Calibration
Sticker
to gage; if reference gage**
record wear dimension(s) in Gage Status Record in Calibration System.
7
Engineering Assistant
Upon
encountering Gage Label on revised drawing
Master
forging or machining drawing
Notify
Calibrations Clerk
that drawing has been changed. GO
BACK TO
STEP 3.
8
Any
team
member
As
needed
to check out gage (typically to use for production job)
Die
number
of job to be gaged (typically from Shop Schedule in
Forge Division,
Operation Order
in Machining Department) listed on Checkout Sheet
Write information
on Measuring
Instrument Verification Log.
9
Any
team
member
Forge
Division: whenever gages are checked out to QC or Production Departments
Gage(s)
Keep
all
gages checked out for QC or Production stored in QC Inspection area
when not in use, until ready to return to Calibrations Clerk.
10
Calibrations Clerk
Upon
Calibrations Clerk's
review of Measuring
Instrument Verification Log.
Measuring
Instrument Verification Log
Notify
QC Supervisor
to have a designated team member return gage(s).
11
Calibrations Clerk
Upon
request to check out gage
Calibration System;
gage
Ensure
that
person checking out gage fills out Measuring
Instrument Verification Log.
12
Calibrations Clerk
At
least
every 2 weeks
Calibration System
Review
status of each gage checked out with person who checked it out.
13
Designated
team member
When
through with gage
-
Return
gage
to Calibrations Clerk;
GO BACK TO STEP 3.
Revision history:
Release Date |
Description of Change |
Owner |
Approver |
12/06/2017 |
Updated to comply with revised Quality Manual and new TOPs format. |
Tim Ellis |
Todd Sheppard |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|