Trinity Forge Training Module

TFTM-WLD1: Welder Qualification SLB WPS-TF-4130


Rev: 12/06/2017

Taught by: Machining Superintendent, Machining QC Leadman

Objective:
bullet ASME Section IX
bullet SLB WPS-TF-4130 or latest version
bullet Part CWS-2-Qualification of Welders and Welding Operators
bullet Specification for the Welding 4130 Low Alloy Steel
bullet Test for Plate of Limited Thickness

Syllabus:
bullet Code: ASME Section IX
bullet WPS-TF-4130 or current revision
bullet Joint type: Groove
bullet Material spec. AISI 4130 Low Alloy Steel
bullet Filler metal: AWS ER 70S-6 / E90T5-D2
bullet Process: GMAW Root/ FCAW Filler
bullet Joint position: 1G Rotated
bullet Material size/thk: 4*4.75 and 0.438 Thick
bullet Preheat Temperature Min/Interpass Temperature Max: 200° F /800° F
bullet Shielding Gas, Mix, flow Rate: Argon/ CO2-90% / 10%, 30-40 CFH; Filler-Argon/CO2 90% / 10%, 30-40CFH
bullet Size of Filler Metals: 0.035"
bullet Current: DCRP
bullet Weld Testing: Visual per QW-302.4 / 2. Transverse side bends per QW-161.1 and QW-462.2  Radiographic examination per QW-191 and QW-302.2
bullet Weld requires elliptical coupon, start and stop overlapped with 0.125 of open root

Completion:  After successful completion of welding and testing the operator is qualified to weld the material and joints that he has been tested on.

The welds that have been made for testing will be submitted to Steel Inspectors of Texas. for qualification. The results of their evaluation will certify or reject the welder operations.

Evidence of welder qualification will be kept in the employee training file. Employee will remain qualified until such time that employee has not welded for a period of six months. The Manager has the right to revoke qualification at any time that employee fails to follow the guidelines set forth in the MPS concerning welding.

Notes: Changes to this training module needs to be coordinated with Steel Inspectors of Texas or other appropriately approved supplier. 

Revision history:

Release Date

Description of Change

Owner

Approver

12/06/2017

Format updated to comply with new TFTM standard, but no content change .

Tim Ellis

Todd Sheppard


















Documents are controlled only when viewed on-line at trinityforge.com in the original English -- printed copies or translations are not controlled documents.
© Trinity Forge & Machine